braid ups status

Query the UPS (NUT) daemon for the currently configured UPS and render a curated human summary or the serialized parsed model as JSON.

Requires UPS support enabled (braid.enable = true and braid.ups.enable = true). With UPS disabled the command prints an enable hint and exits 0 (not an error).

Basic example

sudo braid ups status

Output:

UPS: ups
Status: OL
Battery: 100%
Runtime: 30m 0s
Load: 17% (56 W estimated)
Input: 120.0 V (transfer 88-142 V)
Device: APC Back-UPS ES 550G
Battery manufactured: 2023/04/12
Last test: Done and passed

JSON output

sudo braid ups status --json | jq .

Emits the serialized UpscOutput model. A success body (no top-level error) is trustworthy telemetry: braid faithfully serialized whatever upsc reported. It is not a claim that the UPS is online – on-battery (OB), low-battery (OB LB), and all-unrecognized status sets are all success bodies with no error and no warning.

To judge UPS state, read status_flags: utility power is proven only by the presence of OL with no blocking flag (OB, LB, TESTFAIL, COMMBAD, FSD) – the same affirmative-OL criterion braid’s own mutation preflight uses (see the UPS guide).

Shape:

{
  "status_flags": ["OL"],
  "battery": {
    "charge_pct": 100,
    "runtime_secs": 1800,
    "voltage": "27.0",
    "type": "PbAc",
    "mfr_date": "2023/04/12",
    "runtime_low_secs": 120
  },
  "load_pct": 17,
  "realpower_nominal_watts": 330,
  "input": {
    "voltage": "120.0",
    "transfer_low": "88",
    "transfer_high": "142",
    "sensitivity": "medium"
  },
  "test_result": "Done and passed",
  "device": {
    "model": "Back-UPS ES 550G",
    "mfr": "APC",
    "serial": "3B1234X56789",
    "type": "ups"
  },
  "extra": { "driver.name": "usbhid-ups", "battery.charge.low": "10" }
}

In a success body (the shape above – a reachable UPS, no top-level error), every typed field is always present: a scalar the driver did not report serializes as null rather than being omitted, and the battery, input, and device objects are always present even when all of their fields are null. Test typed fields for a null value, not for a missing key – a has(...) check on any typed key always returns true. status_flags and extra are always present but never null ([] and {} when empty). The only field omitted when absent is the top-level warning (see the table below). Error bodies are the exception – they carry error/detail and none of the typed keys, so a script must confirm there is no top-level error before relying on the rule above.

status_flags lists flags in first-seen ups.status token order (whitespace normalized, duplicate tokens dropped); braid does not sort them, so the order is deterministic for a given UPS state.

extra is a string-keyed map of every upsc line that did not land in a typed field above. Its contents vary with the NUT driver and version (typically driver.* debug keys plus other untyped fields like battery.charge.low or input.voltage.nominal), and values are kept verbatim as strings.

Distinct sentinels cover the common non-OK cases:

ConditionJSONExit code
UPS reachable with populated ups.statusserialized UpscOutput0
UPS reachable but ups.status emptyserialized UpscOutput plus "warning": "ups_status_empty"0
UPS query failed{"error": "query_failed", "detail": "exit <code>: <stderr>"}1
UPS invocation failed (upsc could not run – missing on PATH, killed by signal, or other runner-level failure){"error": "invocation_failed", "detail": "command failed: upsc ups: <reason>"}1
UPS not enabled{"error": "ups_not_enabled"}0

If error or warning is present, do not treat the typed body as healthy UPS state. For these cases, --json writes only to stdout – stderr stays silent so the JSON sentinel can be piped into a single sink (jq, tee, CI logs) without a redundant human error line. Other failure modes, such as malformed config, still print a human error to stderr.

The converse does not hold: the absence of error and warning does not by itself mean the UPS is online – inspect status_flags as above. ups_status_empty fires only when ups.status is empty or missing (no flags to read), so it is not a general health signal.

Flags

FlagEffect
--jsonEmit parsed upsc model as JSON; stable shape for scripts
  • UPS guide – shutdown path, preflight refusal, v1 limitations
  • tui – the TUI’s Data tab shows the same live UPS state
  • doctor – UPS-adjacent configuration checks