This guide covers enabling UPS (uninterruptible power supply) support on a braid NAS via NUT (Network UPS Tools).

Enabling UPS support (braid.enable = true plus braid.ups.enable = true) turns on three behaviors:

  • Orderly poweroff in a long outage. After shutdownAfter on battery, or once the charge drops below shutdownBelowCharge on battery, braid shuts the host down through NUT. The UPS’s own low-battery signal still shuts it down if it comes first. systemd unwinds braid-online.service’s ExecStop, which runs braid lock and cleanly unmounts the pool while the battery still has charge to spare. See Shutdown policy.
  • Preflight refusal without verified utility power. braid add / remove / remove-missing / replace check UPS state at startup and refuse to begin a pool mutation unless the UPS reports verified utility power (OL). This narrows the surface that journal recovery needs to cover.
  • Live state visibility. braid ups status (and the TUI Data tab) show the parsed upsc output: status flags, battery charge, runtime remaining, load, estimated watts, input voltage, and device info.

Scope

v1 supports a single USB-connected UPS on the NAS, monitored by the NAS itself (single-host standalone). Non-USB drivers work through the escape hatch but are not tested.

Minimal config

# configuration.nix
{
  braid = {
    enable = true;
    ups.enable = true;
  };
}

Defaults: name = "ups", driver = "usbhid-ups", port = "auto", shutdownAfter = 300, shutdownBelowCharge = 50. Rebuild and plug the UPS’s USB cable in; NUT’s auto-detect finds the device.

Override the driver or port for non-USB UPSes:

braid = {
  enable = true;

  ups = {
    enable = true;
    name = "myups";
    driver = "apcsmart";
    port = "/dev/ttyS0";
  };
};

Checking status

# Curated human summary
sudo braid ups status

# Machine-readable JSON (stable shape for scripts)
sudo braid ups status --json | jq .

Example human output:

UPS: ups
Status: OL  [ok] on utility power
Battery: 100%
Runtime: 30m 0s
Load: 17% (56 W estimated)
Input: 120.0 V (transfer 88-142 V)
Device: APC Back-UPS ES 550G
Battery manufactured: 2023/04/12
Last test: Done and passed

The human Status: line preserves the raw NUT tokens and adds the same severity model used by the TUI UPS panel: [ok], [warn], [fail], or [skip]. Tags are colored on an interactive TTY and plain under NO_COLOR or when output is piped.

The watts line is labeled estimated and omitted entirely if the UPS does not report both ups.load and ups.realpower.nominal.

The --json output serializes the full parsed model plus braid’s severity verdict, from the same classifier the mutation preflight uses. Only "severity": "online" proves utility power; the ups status page lists every value. Distinct error sentinels are emitted for the common non-OK cases:

ConditionJSON shapeExit code
UPS reachableserialized UpscOutput plus severity0
UPS query failed{"error": "query_failed", "detail": "exit <code>: <stderr>"}. If stderr is blank, detail is just exit <code>.1
UPS invocation failed (upsc could not run – missing on PATH, killed by signal, or other runner-level failure){"error": "invocation_failed", "detail": "command failed: upsc ups: <reason>"}. When upsc is missing, detail ends with -- is braid.packages.nut on PATH?. Other failures, such as a signal kill, get no hint.1
UPS not enabled{"error": "ups_not_enabled"}0

TUI UPS panel

braid tui’s Data tab gains a UPS row when UPS support is enabled. Status text is color-coded by the shared UPS severity model:

  • Green – OL (on utility power).
  • Yellow – OB (on battery, not yet critical).
  • Red – LB / TESTFAIL / COMMBAD / FSD (critical; shutdown imminent or comms-loss).
  • DarkGray – UPS query failed, or no UPS state available yet.

The Shutdown column shows the shutdown policy as braid-ups-guard sees it. On utility power it shows the armed policy dimmed, such as after 5m 0s or <50%. During an outage it counts down (in 3m 12s or <50%), turning red in the last minute. It shows guard down in red when a trigger is set but the guard is not running, overdue when the timer passed its deadline and no forced shutdown followed, and off when both options are null. The countdown comes from the guard’s own clock, so it matches what the guard will do.

During an outage a banner above every tab says how long the UPS has been on battery and when braid shuts down, or why it will not shut down early. It clears once power returns.

The panel polls on the same 5-second cadence as the TUI fans panel. Press r to refresh both pool and UPS probes immediately.

Shutdown policy

braid shuts the host down at the first of three moments:

  1. On battery for shutdownAfter seconds (default 300).
  2. On battery with battery.charge below shutdownBelowCharge percent (default 50).
  3. The UPS reports low battery (OB LB) – the firmware’s own last-resort signal.
braid.ups = {
  enable = true;
  shutdownAfter = 300;      # seconds on battery; null turns the timer off
  shutdownBelowCharge = 50; # percent; null turns the floor off
};

The timer lets short outages ride through. The charge floor covers an aging battery or a grown load that drains faster than the timer assumes. Low battery is the backstop, and fires late: often with about two minutes of estimated runtime left.

Sizing shutdownAfter

Measure the UPS’s runtime at the NAS’s real load (braid ups status shows Runtime while on utility power), then:

shutdownAfter <= runtime x 0.5 - clean-shutdown time - 60 s margin

Keeping about half the battery in reserve is kinder to it and leaves room for an estimate that drifts as the battery ages. If the result is under about two minutes, the UPS is too small for the load. Setting battery.runtime.low or battery.charge.low in NUT does not shut down earlier: NUT raises low battery from those values only with the driver’s ignorelb flag, which braid does not use because it ignores the UPS’s own low-battery signal.

How it works

braid-ups-guard.service polls the UPS every few seconds. The clock starts on the first poll that shows OB and stops only when the UPS reports utility power (OL); a failed query or an unrecognized status leaves it running. A guard restart, such as a nixos-rebuild switch, keeps the outage’s original deadline, and time spent suspended counts.

When a trigger holds, the guard logs one line naming the reason and runs upsmon -c fsd. From there the shutdown is the same as on low battery:

  1. upsmon sets forced shutdown (FSD) on the UPS, writes /run/killpower, and runs systemctl poweroff.
  2. systemd stops braid-online.service, whose ExecStop runs braid lock, which unmounts the pool and closes LUKS.
  3. Late in shutdown, ups-killpower.service tells the UPS to cut its output and restore it when mains returns, so a host set to power on after AC loss boots by itself.
# Why did the NAS shut down? (previous boot)
journalctl -b -1 -u braid-ups-guard

If mains returns while the host is shutting down, a UPS that ignores shutdown.return once on utility power may leave the host off until you power it on.

Turning it off

Set both options to null to shut down only on low battery, as before; the guard is then not installed. Under the default upsmon timings (POLLFREQ = POLLFREQALERT = 5, FINALDELAY = 5) the window between low battery and poweroff is about 10 seconds plus however long braid lock takes.

Mutation refusal when utility power is not verified

With UPS enabled, braid add / remove / remove-missing / replace refuse to start unless upsc returns a non-empty status set that contains OL and no known blocker. The refusal cases are:

  • on-battery (OB)
  • a critical flag the TUI paints red (LB / TESTFAIL / COMMBAD / FSD)
  • OL missing from an otherwise non-blocking status set
  • upsc query or invocation failure (stopped daemon, unknown UPS name, or another fatal NUT error – the message includes upsc’s stderr when present and omits that clause when stderr is blank)
  • an empty or missing ups.status

Known non-critical advisory states such as OL RB, and unknown tokens co-present with OL and no known blocker, still pass: the OL flag is the affirmative utility-power proof, not a guarantee of full battery health. Example refusal:

$ sudo braid add newdisk=/dev/disk/by-id/ata-TOSHIBA_NEW
error: cannot verify UPS is on utility power (UPS reports on-battery)
-- refusing to start add. Check 'braid ups status', restore utility
power, then retry.

Recovery: run braid ups status to confirm, fix the UPS/NUT state, restore utility power, wait for the status to return to a trusted OL, and retry the command.

Two clarifications:

  • braid doctor’s ups_daemon: ok means the configured NUT daemon is reachable; it is not a guarantee that mutating-command preflight will pass. The refusal error from add / remove / remove-missing / replace is the primary channel for the exact mutation-readiness blocker.
  • The OL gate assumes the configured NUT driver reports OL on utility power as documented by NUT. If a device or driver violates that contract, inspect with braid ups status; the recovery is to fix the NUT driver/config or disable braid.ups until the UPS state can be trusted.

doctor checks

braid doctor adds these UPS-adjacent checks when UPS support is enabled:

  • ups daemon – fails if upsc is missing or cannot be spawned, because braid cannot verify the enabled UPS shutdown path. It warns if upsc runs but cannot reach the daemon or exits non-zero. Fix missing upsc by checking the braid wrapper/NUT package path; fix daemon reachability with systemctl status upsd.service.
  • braid-online – fails (high severity) if the pool is mounted but braid-online.service is not active. Without that service active, the UPS shutdown path does not unmount the pool, and the safety guarantee silently breaks. Fix by running systemctl start braid-online.service or braid unlock.
  • ups guard – fails if braid-ups-guard.service is not active while shutdownAfter or shutdownBelowCharge is set. Without the guard, early shutdown is off and only the UPS’s own low-battery signal shuts the host down. Fix with journalctl -u braid-ups-guard and systemctl start braid-ups-guard.service. Skipped when both options are null.
  • ups floor – warns if shutdownBelowCharge is set but the UPS does not report battery.charge, so the charge floor can never fire and only the timer and low battery remain. Check braid ups status; if the UPS cannot report charge, set shutdownBelowCharge = null and rely on shutdownAfter. Skipped when the floor is null or the UPS query fails (the ups daemon check reports that).

Both checks skip when UPS support is disabled, and the braid-online check additionally skips when the pool is not mounted (there is nothing for the UPS shutdown path to unmount).

v1 limitation: no async alert

There is no asynchronous notification when the UPS goes on battery or loses comms in v1. Operators who are not actively watching braid ups status or the TUI will not see those conditions – only the orderly shutdown (see Shutdown policy) is automatic.

This is deliberate: integrating UPS events into braid’s shared alert model requires splitting AlertCause by persistence semantics (latched-until-ack for disk errors, active-while-condition-holds for live UPS states) and is out of scope for v1. See decisions/020-ups-integration.md for the open-question status.

If you need asynchronous UPS notifications today, wire NUT’s NOTIFYCMD directly – braid does not touch it.