Superseded by 012-intent-cli.md and 017-runtime-disk-membership.md.

Decision: Disk Pool Management

Principle: CLI-owned membership

Context

braid-add-disk exists and is tested. The pool still needs graceful disk removal, status reporting, and a clear replace workflow. All operations must follow the same config-first pattern: edit braid.disksnixos-rebuild switch → run CLI tool.

Principle: config-first applies symmetrically

Config-first is not just for adding disks. Every pool mutation follows the same workflow:

  • Add: declare disk in braid.disks → rebuild → braid-add-disk
  • Remove: remove disk from braid.disks → rebuild → braid-remove-disk
  • Replace: remove dead disk + add replacement in braid.disks → rebuild → braid-add-disk

Symmetric guards enforce this:

  • braid-add-disk refuses disks not in config
  • braid-remove-disk refuses disks still in config

braid-remove-disk spec

Three-tier logic

  1. Target mapper exists and is open, verified to map to the requested by-id disk → graceful btrfs device remove /dev/mapper/xxx (migrates data off the device)
  2. Target is absent/unopenable and pool shows a missing device → btrfs device remove missing
  3. Otherwise → fail with clear diagnostic

Graceful remove is preferred when possible. It avoids relying on RAID1 reconstruction and eliminates ambiguity if more than one device is missing.

LUKS cleanup

After btrfs remove, cryptsetup close the mapper. Best-effort:

  • Success → print “disk fully released” (safe to physically pull)
  • Failure (busy) → print actionable next steps (lsof/fuser + retry), exit non-zero

No passphrase required

Remove does not need a passphrase. The disk is already unlocked or already gone. Root access + config guard + typed confirmation is sufficient.

Confirmation

Normal remove (pool stays RAID1 with 2+ disks):

Type 'remove this disk' to confirm:

Removing would drop below 2 disks (losing redundancy):

WARNING: This leaves 1 disk with no RAID1 redundancy.
A single disk failure will cause data loss.

Type 'remove this disk without redundancy' to confirm:

Warn but allow dropping to 1 disk — consistent with the single-disk start story.

Reboot-in-between safety

If the user reboots between nixos-rebuild switch (which removes the LUKS entry) and running braid-remove-disk, the disk won’t auto-unlock. This is safe: principle #1 (resilient boot) ensures the system boots and is reachable via SSH. The pool requires explicit --allow-degraded (or autoUnlock.allowDegraded) to mount degraded. The CLI handles both paths (tier 1 if disk is still somehow open, tier 2 if it’s absent).

braid-status spec

Default output

Pool health summary: drive count, RAID profile, total/used/free capacity, degraded/missing state, last scrub result. Per-disk detail: model, serial, mapper name, btrfs devid, read/write/corruption error counters, LUKS UUID, present/missing state.

--json

Machine-readable output for monitoring and automation.

Replace workflow

Replace uses braid-add-disk, which already auto-evicts missing devices during rebalance.

Workflow:

  1. Remove dead disk from braid.disks, add replacement
  2. nixos-rebuild switch
  3. sudo braid-add-disk /dev/disk/by-id/<new-disk>

Auto-evict is specifically for missing/dead devices. Planned removal of a healthy disk uses braid-remove-disk.

Future vision

Document only — do not build yet.

Unified CLI: braid plan (dry-run diff of config vs live state), braid apply (execute with checkpoints and resumability), braid status, braid replace-disk <old> <new>.

Phased roadmap:

  1. Ship braid-remove-disk and braid-status (solid primitives)
  2. Read-only planner (braid plan)
  3. Executor with checkpoints (braid apply)
  4. First-class braid replace-disk
  5. braid-status --json

Nix config remains source of truth throughout. The workflow evolves from edit → rebuild → script to edit → rebuild → plan → apply, but the principle is unchanged.

CLI shape

Separate scripts (braid-add-disk, braid-remove-disk, braid-status) — not a unified CLI yet. The unified braid command is future work that depends on proven primitives.

See

  • modules/braid/options.nixbraid.disks option definition
  • modules/braid/storage.nix — config export and LUKS entry generation